> For the complete documentation index, see [llms.txt](https://help.bioinsight.illumina.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.bioinsight.illumina.com/infectious-disease/dragen-16s-plus/dragen-16s-plus/how-to-set-up-and-run-an-analysis.md). Agents can also search and read this documentation through its [MCP server](https://help.bioinsight.illumina.com/~gitbook/mcp).

# How to set up and run an analysis

1. Launch the DRAGEN 16S Plus BaseSpace app, which can be found in the "Dragen" and "Infectious Disease + Microbiology" app collections.
2. Enter a name for the Analysis.
3. Choose either "Project" or “Biosample list” as input type. When a Project is selected, the app will attempt to find all FASTQ files in that Project and run analyses on them.
4. Select a reference database. Only one database can be selected per analysis. If "Custom Database" is selected, the "Custom database specification" section is enabled to allow entry of a custom reference FASTA for taxonomic classification. See [Custom database FASTA file format](https://help.bioinsight.illumina.com/infectious-disease/dragen-16s-plus/dragen-16s-plus/how-to-set-up-and-run-an-analysis/custom-database-fasta-file-format.md) for further details.
5. Analysis Options:

* Perform read QC (Quality Control)
  * If checked, reads are pre-processed using quality metrics before analysis. For paired-end data, both read1 and read2 must pass QC filtering for the read pair to be used for analysis.
  * If unchecked, read quality metrics are calculated, but reads are not trimmed or filtered before analysis.

6. Specify a "Read count threshold". The read count threshold is a reporting threshold representing the number of reads (or read pairs for paired-end data) that must be classified to a taxonomic identifier for the taxonomic identifier to be included in summary reports. It is an integer with a valid range of 0 to 1000, inclusive. The default value is 0, meaning that no filtering is applied to results and all taxa with classified reads are reported.
7. Select the Project where the Analysis Output should be saved.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.bioinsight.illumina.com/infectious-disease/dragen-16s-plus/dragen-16s-plus/how-to-set-up-and-run-an-analysis.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.