Adding variants to a case from the Analysis Tools tab
You can add variants that are not in the uploaded VCF or called from FASTQ data.
Currently supported variant types include SNV/indel, CNV, UPD, LOH/ROH, and STR. SV support is planned for future releases.
Adding variants is useful when you need to:
Complement NGS results with findings from other genetic tests, such as long-read sequencing, optical mapping, CGH, SNP arrays, karyotyping/FISH, repeat-primed PCR, MLPA, or Southern blot.
Report adjacent CNV calls as one CNV event.
Report adjacent variants together as one multi-nucleotide variant (MNV).
Adding variants to a case ensures that all relevant findings are visible in the case review and can be considered during interpretation.
When reviewing a case, to show only variants entered outside the automated pipeline, apply the Manually added variants filter.

The Variant page for a manually added variant has a blue border and a "Manually added variant" label.

Adding a variant to a case from the Analysis Tools tab
Prerequisite: You need the relevant permissions.
In the Analysis Tools tab, select Manually add a variant () in the upper-right corner.

Select a variant type.
Enter required details for the selected variant type.
Chromosome
Position
REF
ALT
Zygosity in analyzed samples

Chromosome
Position Start
Position End
REF (v100.40 and earlier). On v100.41 and later, REF is set to
Nand is not shown.Type
CNV:
DELorDUPUPD:
IUPDMAT(maternal isodisomy),IUPDPAT(paternal isodisomy),HUPDPAT(paternal heterodisomy), orHUPDMAT(maternal heterodisomy)
Zygosity in analyzed samples
Quality metrics (v100.41 and later)
Variant quality:
HIGH,MODERATE, orLOW. Default value isHIGH.CN (copy number)
Mosaic flag and Mosaic fraction

Chromosome
Position Start
Position End
REF (v100.40 and earlier). On v100.41 and later, REF is set to
Nand is not shown.Zygosity
Quality metrics (v100.41 and later)
Variant quality:
HIGH,MODERATE, orLOW. Default value isHIGH.CN (copy number)
Mosaic flag and Mosaic fraction

Chromosome
Position
REF Repeats Number
ALT Repeats Number
Repeats Unit
Zygosity in analyzed samples

Select Create Variant.
Result:
The variant is added to the case.
Variant annotation: see below.
v100.41 and later
On v100.41 and later, manually added variants go through a full annotation pipeline.
Annotation starts, and a notification tells you that it has started. You cannot finalize the case while annotation is in progress.
When annotation finishes and you get a success message, select Open variant to open the Variant page.

Last updated
Was this helpful?