For the complete documentation index, see llms.txt. This page is also available as Markdown.

Adding variants to a case from the Analysis Tools tab

You can add variants that are not in the uploaded VCF or called from FASTQ data.

Currently supported variant types include SNV/indel, CNV, UPD, LOH/ROH, and STR. SV support is planned for future releases.

Adding variants is useful when you need to:

  • Complement NGS results with findings from other genetic tests, such as long-read sequencing, optical mapping, CGH, SNP arrays, karyotyping/FISH, repeat-primed PCR, MLPA, or Southern blot.

  • Report adjacent CNV calls as one CNV event.

  • Report adjacent variants together as one multi-nucleotide variant (MNV).

Adding variants to a case ensures that all relevant findings are visible in the case review and can be considered during interpretation.

When reviewing a case, to show only variants entered outside the automated pipeline, apply the Manually added variants filter.

You can also add a variant from the Variant visualization tool. See Adding variants to a case from the Variant visualization tool.

Adding a single nucleotide variant to a case on v100.41.

The Variant page for a manually added variant has a blue border and a "Manually added variant" label.

Manually added variant label.

Adding a variant to a case from the Analysis Tools tab

Prerequisite: You need the relevant permissions.

1

In the Analysis Tools tab, select Manually add a variant () in the upper-right corner.

2

Select a variant type.

3

Enter required details for the selected variant type.

  • Chromosome

  • Position

  • REF

  • ALT

  • Zygosity in analyzed samples

  • Chromosome

  • Position Start

  • Position End

  • REF (v100.40 and earlier). On v100.41 and later, REF is set to N and is not shown.

  • Type

    • CNV: DEL or DUP

    • UPD: IUPDMAT (maternal isodisomy), IUPDPAT (paternal isodisomy), HUPDPAT (paternal heterodisomy), or HUPDMAT (maternal heterodisomy)

  • Zygosity in analyzed samples

  • Quality metrics (v100.41 and later)

    • Variant quality: HIGH, MODERATE, or LOW. Default value is HIGH.

    • CN (copy number)

    • Mosaic flag and Mosaic fraction

  • Chromosome

  • Position Start

  • Position End

  • REF (v100.40 and earlier). On v100.41 and later, REF is set to N and is not shown.

  • Zygosity

  • Quality metrics (v100.41 and later)

    • Variant quality: HIGH, MODERATE, or LOW. Default value is HIGH.

    • CN (copy number)

    • Mosaic flag and Mosaic fraction

  • Chromosome

  • Position

  • REF Repeats Number

  • ALT Repeats Number

  • Repeats Unit

  • Zygosity in analyzed samples

4

Select Create Variant.

Result:

  • The variant is added to the case.

  • Variant annotation: see below.

v100.41 and later

On v100.41 and later, manually added variants go through a full annotation pipeline.

Annotation starts, and a notification tells you that it has started. You cannot finalize the case while annotation is in progress.

When annotation finishes and you get a success message, select Open variant to open the Variant page.

Variant annotation success message.

The latest available pipeline version is used for annotation of variants added to a delivered case, regardless of the pipeline version selected in Settings. The pipeline version used for the annotation is recorded in the Activity.

v100.40 and earlier

On v100.40 and earlier, manually added variants are not annotated and automatic ACMG scoring is not applied.

In the variant table, you cannot sort these variants by columns that depend on annotation, such as AI Rank.

Last updated

Was this helpful?