Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Minimal Checklist

This section provides a succinct checklist of critical Quality Control (QC) metrics for evaluating DRAGEN run performance. These metrics are located in the standard CSV output files in the run directory.

1. Basic Run & Alignment QC

Source File: <output_prefix>.mapping_metrics.csv Default Status: Enabled

Note that mapping metrics are computed on the raw input sample (prior to optional UMI collapsing).

Metric Name
Critical Trend / Success Criteria

Total input reads

Volume check: Confirm read count matches sequencer output and assay expectations. E.g. ~600–900M reads for 30X human WGS.

Q30 bases

Base quality: Generally > 85–90%. A global drop indicates chemistry or flow cell issues.

Mapped reads

Alignment success: Aim for > 95% (human WGS). Low mapping (< 90%) suggests wrong reference, contamination, or poor library quality.

Soft-clipped bases (R1/R2)

Adapter/quality trimming: Typical values < 2–3% for high-quality libraries. Values > 5% indicate adapter read-through, short inserts, or degraded DNA.

Estimated sample contamination

Purity check: Requires --qc-detect-contamination=true. For germline samples, > 1–2% can impact variant calling accuracy.

Duplicate reads

Library complexity: Germline WGS typically < 20%. WES and targeted assays often show 20–50%, which is expected given the reduced target space.

Properly paired reads

Fragment integrity: Should be > 90% for high-quality libraries. Low values indicate fragment issues or reference mismatch. RNA-seq expects lower rates due to splicing.

Reads with MAPQ [40:inf)

High-confidence alignments: For human WGS, expect > 80% with MAPQ ≥ 40. Lower values suggest alignment ambiguity or wrong reference.

2. FastQC (Sequence Composition)

Source File: <output_prefix>.fastqc_metrics.csv Default Status: Enabled

Note that FastQC metrics are computed on the raw input sample (prior to optional UMI collapsing).

Metric Name
Critical Trend / Success Criteria

Positional base mean quality

Cycle decay: Identify quality drop-off at read ends or specific cycles indicating fluidics issues.

Read GC content

Contamination/bias: Deviation from expected distribution (e.g. human ~40–45% GC) suggests contamination or severe PCR bias.

Sequence positions (adapters)

Adapter content: High levels indicate untrimmed adapters or short inserts, leading to elevated soft-clipped bases in mapping metrics.

3. UMI QC (Applies Only to UMI Designs)

Source File: <output_prefix>.umi_metrics.csv Default Status: Enabled as part of the UMI pipeline (requires --umi-enable=true)

Metric Name
Critical Trend / Success Criteria

Consensus reads

Conversion efficiency: Low ratio relative to input reads suggests low molecular complexity or insufficient sequencing depth.

Mean family size

Saturation: Family sizes near 1.0 indicate under-sequencing. Very high sizes may indicate excessive PCR amplification.

4. Coverage QC

Source File: <output_prefix>.*_coverage_metrics.csv (e.g. wgs_coverage_metrics.csv or target_bed_coverage_metrics.csv) Default Status: Enabled

Please note coverage metrics are computed post read deduplication or UMI collapsing. Reads with MAPQ=0 are ignored.

Metric Name
Critical Trend / Success Criteria

Average alignment coverage over target bed / genome

Depth check: Primary driver of sensitivity. Ensure it meets assay target (e.g. 30× germline, 100×+ somatic).

Uniformity of coverage (PCT > 0.2× mean)

Bias check: Low uniformity indicates coverage bias (e.g. GC bias), leading to variant calling blind spots. Germline WGS typically ≥ 80–90%.

PCT of genome with coverage [x: inf)

Callability: E.g. PCT ≥ 20×. Germline WGS typically requires > 95% at 20×.

Aligned bases in target bed / genome

Yield: Total usable data for normalizing performance across runs or flow cells.

5. Variant-Level Sanity Check (Optional)

Source File: <output_prefix>.vc_metrics.csv Default Status: Conditional (variant caller enabled)

Metric Name
Critical Trend / Success Criteria

Ti/Tv Ratio

Biological plausibility: For human germline WGS, expect ~1.9–2.2. Values < 1.7 often indicate elevated false-positive rates.

Note: Ti/Tv is a biological sanity check, not a standalone QC pass/fail metric. Expected values depend on organism, assay type, and genomic region.

How to Use This Checklist

  • Treat this as a minimum QC review, not an exhaustive list.

  • Values outside these ranges warrant investigation but are not automatic failures.

  • Some metrics are assay-specific and may require optimization for particular use cases.

Last updated

Was this helpful?