ADAT Content - 9.5k
This page describes the output from the 9.5k SomaSeq Discovery assay, which differs slightly from the 6k assay. Use this for ADATs made on DRAGEN Protein Quantification v2.0 and higher.
The primary output file of DRAGEN Protein Quantification is the ADAT. One ADAT is produced for each normalization step performed. The final ADAT produced (<output_file_prefix>_Step3_SampleNorm.adat) has the normalized counts at the end of the full normalization process.
Supported sample types: Plasma, Serum, CSF, and MultiMatrix (with user-defined tissue types).
There are four key components to the ADAT: the header, SOMAmer metadata, sample metadata, and counts.

ADAT Header
Version
Version of the software used during analysis
Title
User reference for the analysis
SOMAmerReferenceSource
SOMAmer metadata version used during analysis
AssayType
Assay types used
AssayVersion
Version of the SomaSeq Discovery assay (e.g., SomaSeq Discovery v2)
AssayRobot
Liquid handling robot
RunId
Unique identifier for the run (created by sequencing instrument)
Instrument Type
Instrument used for sequencing
Flowcell
Flowcell used for sequencing
YieldDemux
Total number of reads that are demultiplexed
YieldQ30Demux
Total number of reads that are demultiplexed with a passing QC score
Q30WeightedMean
Q30 primary sequencing metric, computed as the Q30 weighted mean across lanes
CreatedDate
Date the run was performed
StudyOrganism
Sample organism (human)
StudyMatrix
Matrix used in study (Serum, Plasma, CSF, or MultiMatrix)
CalibratorId
Lot number(s) of the calibrator samples per plate (JSON format, e.g., {"PlateId":"240320B"})
ProcessSteps
The process steps that occurred to produced the counts in the current ADAT
HybQC_Ref
Reference value for Hyb QC calculation
HybQC_Delta
Threshold delta for HybQC pass/flag determination. If a sample's HybQC value is less than or equal to this threshold, the sample receives PASS.
PlateSOMAmerNormReads_PassFlag
PASS/FLAG for each plate. If greater than 70% of Blank Samples have SOMAmerNormReads_PassFlag = FLAG, PlateSOMAmerNormReads_PassFlag shall be WARNING. Otherwise, it shall have the value "PASS".
PlatformSpecificPlateScale_ScaleFactor
Scale factors for the PlateScale normalization step, when compared to a platform specific reference. The reference is based on data from the sequencing instrument used for the run.
PlatformSpecificCalibrateTailPercent
Percent of Platform Specific Calibration scale factors in tails (outside of the acceptable range of 0.6-1.4) for each plate when compared to a reference. The platform specific reference is based on data from the sequencing instrument used for the run.
PlatformSpecificCalibrateTailPercent_PassFlag
PASS/WARNING for each plate. If PlatformSpecificCalibrateTailPercent for a plate is greater than .15, this value shall be "WARNING". If it is less than or equal to .15, it shall be "PASS".
PlatformSpecificQCCheckTailPercent
Percent of QC scale factors in tails for each plate from comparing Serum QC samples on MultiMatrix plates to their corresponding calibration samples after plate scaling. This is only reported for MultiMatrix.
PlatformSpecificQCCheckTailPercent_PassFlag
PASS/WARNING for each plate. If PlatformSpecificQCCheckTailPercent for a plate is greater than .15, this value shall be "WARNING". If it is less than or equal to .15, it shall be "PASS". This is only reported for MultiMatrix.
CrossPlatformPlateScale_ScaleFactor
Scale factors for the PlateScale normalization step, when compared to a universal reference made with NovaSeq X data.
CrossPlatformCalibrateTailPercent
Percent of Cross Platform Calibration scale factors in tails (outside of the acceptable range of 0.6-1.4) for each plate when compared to a reference. The cross platform reference is based on data from NovaSeq X runs.
QCCheckTailPercent
Percent of QC scale factors in tails for each plate.
QCCheckTailPercent_PassFlag
PASS/FAIL for each plate. If QCCheckTailPercent for a plate is greater than .15, this value shall be "FAIL". If it is less than or equal to .15, it shall be "PASS".
IntraPlateMedianCV
Median Percent CV metric for each plate, computed after Sample Normalization, providing:
(sample Standard Deviation of calibrator samples/Mean of calibrator samples)*100
(sample Standard Deviation of QC samples/Mean of QC samples)*100
IntraPlateQ75CV
Same as IntraPlateMedianCV (above) but showing 75th percentile of Percent CV instead of median
IntraPlateQ90CV
Same as IntraPlateMedianCV (above) but showing 90th percentile of Percent CV instead of median
InterPlateMedianCV
Median Percent CV metric across plates, providing:
(sample Standard Deviation of plate mean count in calibrator samples/Mean of plate mean count in calibrator samples)*100
(sample Standard Deviation of plate mean count in QC samples/Mean of plate mean count QC samples)*100
Provided only if there are 4 or more plates in the analysis
InterPlateQ75CV
Same as InterPlateMedianCV (above) but showing 75th percentile of Percent CV instead of median
InterPlateQ90CV
Same as InterPlateMedianCV (above) but showing 90th percentile of Percent CV instead of median
MedianS2B
Median Signal to Background metric for each plate based on human somamers after Plate Normalization, providing:
Median Calibrator/Median Blank
Median QC/Median Blank
GeneratedBy
Version of SomaData parser used to write ADAT (ex. SomaData_1.0.0)
Sample Metadata
SampleID
Sample identifier
PlateId
Unique plate identifier
MatrixTubeBarcode
Matrix tube barcode scanned during library prep
BatchID
User-provided batch identifier
InputType
Sample type specified in manifest file.
Examples: Plasma, Serum, CSF, MultiMatrix-<tissuetype>, Blank
MatrixType
Matrix used.
Examples: Plasma, Serum, CSF
SampleType
Type of sample processed.
Examples: Plasma, Serum, CSF, Blank, QC, Calibrator
Control
The control type for the sample. Values: Calibrator, QC, Blank, or empty (for non-control samples).
ControlID
ID of the calibrator, QC, or blank lot (applied to controls only).
KitType
Kit type associated with the sample plate. Values: Plasma, Serum, CSF, or MultiMatrix.
ScriptsVersion
Version of ILASS automation scripts used during library prep (e.g., 3.2.7).
ProbePlate
Probe plate lot number, from library prep
SOMAmerBeadPlate
SOMAmer bead plate lot number. For Plasma/Serum/CSF: SBP1 barcode. For MultiMatrix: MBP barcode.
WellPosition
Location of the sample on the 96 well plate (A1-H12)
Project
(Optional) User-provided project identifier. Multiple projects per plate are supported.
SOMAmerReads
Number of raw counts human SOMAmer reads (excluding control reads)
SOMAmerReads_PassFlag
This flag indicates whether a non-blank sample meets specifications for number of SOMAmer reads. For non-blank samples:
SOMAmerReads ≥ 10 million = PASS
SOMAmerReads < 10 million = FLAG
Not applied to blank samples.
SOMAmerNormReads
Number of normalized counts human SOMAmer reads at plate scale normalization step (excluding control reads)
SOMAmerNormReads_PassFlag
This flag indicates whether a blank sample meets the specifications for number of normalized SOMAmer reads. For blank samples:
SOMAmerNormReads ≤ 20 million = PASS
SOMAmerNormReads > 20 million = FLAG
Not applied to non-blank samples.
RefCorr
Spearman correlation value for comparing samples to the plasma, serum, or CSF reference.
HybQC
Hyb QC metric value for the sample, representing the deviation from expected Tm control distribution. Replaces EmpiricalHybTemp from earlier versions.
HybQC_PassFlag
This flag indicates if a sample meets the specification for Hyb QC.
HybQC ≤ HybQC_Delta (from ADAT header) = PASS
HybQC > HybQC_Delta or missing = FLAG
HybNorm_1_ScaleFactor
The hybridization control scale factor
HybNorm_PassFlag
This flag indicates whether the HybNorm_1_ScaleFactor is within the specified acceptance criteria range of 0.4–2.5. CSF samples (excluding controls) have a different acceptance criteria range of 0.2-5.0.
MedNormInt_<dilution>_ScaleFactor
The MedNormInt scale factor for the dilution group
MedNormInt_PassFlag
This flag indicates whether all dilution group scale factors are within the specified acceptance criteria range of 0.4–2.5 for the MedNormInt step. Applies to blank and calibrator samples.
MedNormExt_<dilution>_ScaleFactor
The MedNormExt scale factor for the dilution group (Plasma/Serum/CSF only; not applicable to MultiMatrix)
MedNormExt_PassFlag
This flag indicates whether all dilution group scale factors are within the specified acceptance criteria range of 0.4–2.5 for the MedNormExt step. CSF samples (excluding controls) have a different acceptance criteria range of 0.125-8.0. Applied to QC and serum/plasma/CSF samples. Not applicable to MultiMatrix.
CrossPlateMedNormInt_all_ScaleFactor
The CrossPlateMedNormInt scale factor specific to MultiMatrix samples
CrossPlateMedNormInt_PassFlag
This flag indicates whether the CrossPlateMedNormInt scale factor is within the specified acceptance criteria range of 0.4–2.5 for MultiMatrix samples
RowCheck_PassFlag
This flag indicates whether the sample's plate failed and if not whether all row scale factors are within the specified acceptance criteria range
SOMAmer Metadata
SeqId
Unique sequence identifier for the SOMAmer
SeqIdVersion
SOMAmer sequence version
SomaId
SomaLogic-provided identifier
Target
Protein target identifier
Target Full Name
Protein target full name
Type
Target type (protein)
UniProt ID
UniProt identifier
Entrez Gene ID
Entrez Gene identifier
Entrez Gene Symbol
Entrez Gene symbol
HybControl
True if the SOMAmer is a hyb control, else False
Organism
Organism (e.g. Human, Mouse) of the SOMAmer
PlatformSpecificCalibrate_<PlateId>_ScaleFactor
Scale Factor for Platform Specific Calibration
CrossPlatformCalibrate_<PlateId>_ScaleFactor
Scale Factor for Cross Platform Calibration
QCCheck_<PlateId>_ScaleFactor
Scale Factor for QC Check
Dilution
Dilution group classification for the SOMAmer
DRC_Level.<KitType>
Compression of SOMAmer range that occurred during the assay.
References
References used in the analysis. For Plasma/Serum: includes Ref.MedNormExt.{type} and Ref.QCCheck.{type}. Bridging references follow the format Ref.Bridging.<CalibratorId>.<Instrument>.<Flowcell>.v2.
Units
Units of matrix content
Last updated
Was this helpful?