SomaSeq Automation System Output Files
The SomaSeq Automation System Output File (SomaSeqAS output file) is a .csv file that is produced after automated library prep is completed. The output file is saved on the Tecan PC in C:\OutputFiles with the filename format: BatchID_PlateBarcode_output_OutputDate.csv.
It contains the following fields:
Lanes
Optionally contains information about lane splitting. Values are left blank by default. Refer to Lane Splitting and Multi-Analysis by Project for more detail.
Sample ID
Identifier per sample. Specified in Sample Manifest prior to automation. For controls (QC, Blanks, Calibrators), the sample ID is pre-filled in the template files. ILASS appends a GUID to control Sample IDs to ensure uniqueness when combining plates.
Well Position
Well position of the sample with UDI set appended. Format: {Set}-{Well} (e.g., A-A01, B-H12). UDI set (A, B, C, or D) is determined by the barcode on the index plate scanned by the SomaSeq Automation System.
Project
Optionally contains information about what project the output file should contain. Multiple values are allowed and this field can be blank for all or some samples. Refer to Lane Splitting and Multi-Analysis by Project for more detail.
PlateBarcode
Barcode associated with sample plate. Specified in Sample Manifest prior to automation. Min 8, max 36 alphanumeric characters. Dashes and underscores are permitted but cannot be the first or last character.
InputType
Sample input type. Permitted values: Blank, Plasma, Serum, CSF, or MultiMatrix-<tissuetype> where <tissuetype> is an alphanumeric string (max 36 characters). Specified in Sample Manifest prior to automation.
Control
The control type for the sample. Permitted values: Blank, Calibrator, QC, or empty (for non-control samples). If Control = Blank, then InputType must be Blank. For Plasma/Serum/CSF, if Control = QC or Calibrator, then InputType must match the respective sample type.
ControlID
Lot number for associated calibrator, QC, or blank sample. Generated by ILASS from information supplied on the Scan or Type Consumables screen. Expected format: NNNNNN.
KitType
The kit type associated with the sample plate. Permitted values: Plasma, Serum, CSF, or MultiMatrix. Generated by ILASS from the Kit Type selected on the Define Batch screen.
BatchID
User-provided batch identifier. Generated by ILASS from the Batch ID supplied on the Define Batch screen. No commas or asterisks allowed.
ProbePlate
Proteomics Probe Plate barcode scanned during library prep. The last two characters indicate the Probe Pool Lot (e.g., "-AA" or "-AB").
SOMAmerBeadPlate
SOMAmer Bead Plate barcode scanned during library prep. For Plasma/Serum/CSF sample types, this is the SOMAmer-Bead Plate 11K v5.0 Dil1 barcode (format: SBP1-XXXXXXXXXX). For MultiMatrix sample types, this is the SOMAmer-Bead Plate 11K Single Dilution barcode (format: MBP-XXXXXXXXXX).
MatrixTubeBarcode
Barcode associated with matrix tube. Specified in Sample Manifest prior to automation. Min 5, max 36 alphanumeric characters. This field is optional.
ScriptsVersion
Version of automation scripts referenced by ILASS (e.g., 3.1.5, 3.1.6).
The SomaSeq output file is accepted as an input by the Run Planning tool or local DRAGEN server, which populates information required to generate the sample sheet.
Last updated
Was this helpful?

