Prerequisites

Before setting up and running SomaSeq Discovery, ensure that the necessary software, tools, and configurations are in place. These prerequisites can vary depending on the environment used to run the secondary analysis (e.g., via cloud or locally). Follow the steps below to configure instrument and software appropriately.

Instrument Software Prerequisites

  • Control Software (v1.8.0 or later)

  • SomaSeq Discovery custom recipe XML file installed on the sequencing instrument. Illumina provides the file.

    • SomaSeq Discovery NovaSeq 6000 v1.0.xml

  • SomaSeq Automation System output files, depending on the sequencing set up.

    • NovaSeq 6000 (S4 flow cell)

      • Recommended: Two SomaSeq Automation System output files / 192 reactions

  • Control Software (v1.4.0 or later for SomaSeq Discovery v2)

  • SomaSeq Discovery custom recipe XML file installed on the sequencing instrument. Illumina provides the file.

    • SomaSeq Discovery NovaSeq X 5B v3.0.xml

    • SomaSeq Discovery NovaSeq X 10B v3.0.xml

    • SomaSeq Discovery NovaSeq X 25B 100 cycles v3.0.xml

    • SomaSeq Discovery NovaSeq X 25B 200 cycle v1.0.xml (upon request only)

    • SomaSeq Discovery NovaSeq X 25B 300 cycle v1.0.xml (upon request only)

  • SomaSeq Automation System output files, depending on the sequencing set up.

    • NovaSeq X (5B flow cell)

      • Recommended: One SomaSeq Automation System output file / 96 reactions

    • NovaSeq X (10B flow cell)

      • Recommended: Two SomaSeq Automation System output files / 192 reactions

    • NovaSeq X (25B flow cell)

      • Recommended: Six SomaSeq Automation System output files / 576 reactions

Cloud Secondary Analysis Prerequisites

  • BaseSpace Sequence Hub (BSSH) or BioInsight Platform Core (formerly ICA) account.

    • All BSSH and Platform Core subscriptions come with access to the DRAGEN Protein Quantification application.

    • [Platform Core subscribers] To view results in Platform Core, select Platform Core Run Storage in BSSH Workgroup Settings.

    • For more information about which subscription is best for your use case, contact your FAS or TAM.

  • For information on registering a BaseSpace Sequence Hub or Platform Core account, refer to the account management documentation or connect with an Illumina Account Manager.

Note: When performing analysis with more than one plate, each plate must have their own unique plate barcode value.

Local Secondary Analysis Prerequisites

  • Root privileges for install

  • Willingness to install Docker (included in DRAGEN Application Manager installation)

  • DRAGEN Phase 4 server with the minimum disk space:

    • NovaSeq6000, S4 flow cell: ≥ 10GB

    • NovaSeqX, 5B flow cell: ≥ 20 GB

    • NovaSeqX, 10B flow cell: ≥ 20 GB

    • NovaSeqX, 25B flow cell: ≥ 35 GB

  • DRAGEN Phase 4 server with the minimum available RAM:

    • NovaSeq6000, S4 flow cell: ≥ 75GB

    • NovaSeqX, 5B flow cell: ≥ 80GB

    • NovaSeqX, 10B flow cell: ≥ 80GB

    • NovaSeqX, 25B flow cell: ≥ 95GB

  • External storage drive mounted to a DRAGEN server. This drive must be mounted through a network share and support NFS/CIFS/SMB protocols. Read and write permissions are required to use this network share. For more information, please refer to the SomaSeq Discovery Product Documentation.